Would like to obtain more info and learn more of its applications?
Research Anemometers
Research Anemometers
Research Anemometers
R3 Anemometers
The Solent R3 research range of anemometers has been designed with researchers in mind who need to determine fluxes using the eddy covariance technique. The range provides U, V, W and SOS (sonic temperature) outputs, which may be logged using the free Gill WindCom software. All units are served with common electronics and software and may be supplied with accessories that include cables, power supplies and sensor input units (analogue inputs).

Specifications | R3-50 | R3-100 / R3A-100 |
---|---|---|
Ultrasonic Output Rate | 50 Hz | 100 Hz |
Wind Speed Range | 0-45 m/s | 0-45 m/s |
Wind Direction Range | 0-359 no dead band | 0-359 no dead band |
Operating Temp Range | -40ºC to +60 ºC | -40 ºC to +60 ºC |
Moisture Protection | IP65 | IP65 |
External Construction | Aluminium & Carbon Fibre | Aluminium & Carbon Fibre |
Digital O/P Options | RS422 (RS232 optional) | RS422 & RS232 |
NMEA O/P | N/A | N/A |
Analogue Outputs | 7 (via optional PCIA) | 7 (via PCIA) |
Analogue Output Resolution | 14 bit | 14 bit |
Analogue Input | 6 (optional SIU) | 6 (optional SIU) |
Analogue I/P resolution | 14 bit | 14 bit |
Speed of Sound O/P | Available | Available |
Sonic Temp Output | Available | Available |
PRT Input | Via optional SIU | Via optional SIU |
Inclinometer | N/A | Option |
Head Symmetry | Symmetrical | Symmetrical / Asymmetric |
Calibration | Custom | Custom |
Transit Case | Optional | Supplied |
HS Anemometers
The Solent HS research range of anemometers has been designed with researchers in mind who need to determine fluxes using the eddy covariance technique.
The range provides U, V, W and SOS (sonic temperature) outputs, which may be logged using the free Gill WindCom software.
All units are served with common electronics and software and may be supplied with accessories that include cables, power supplies and sensor input units (analogue inputs).

Specifications | HS-50 | HS-100 |
---|---|---|
Ultrasonic Output Rate | 50 Hz | 100 Hz |
Wind Speed Range | 0-45 m/s | 0-45 m/s |
Wind Direction Range | 0-359 no dead band | 0-359 no dead band |
Operating Temp Range | -40ºC to +60 ºC | -40 ºC to +60 ºC |
Moisture Protection | IP65 | IP65 |
External Construction | Stainless Steel | Stainless Steel |
Digital O/P Options | RS422 & RS232 | RS422 & RS232 |
NMEA O/P | N/A | N/A |
Analogue Outputs | 7 (via optional PCIA) | 7 (via PCIA) |
Analogue Output Resolution | 14 bit | 14 bit |
Analogue Input | 6 | 6 |
Analogue I/P resolution | 14 bit | 14 bit |
Speed of Sound O/P | Available | Available |
Sonic Temp Output | Available | Available |
PRT Input | Available | Available |
Inclinometer | Fitted | Fitted |
Head Symmetry | Horizontal | Horizontal |
Calibration | Custom | Custom |
Transit Case | Supplied | Supplied |
WindDisplay
WindDisplay is compatible with the WindSonic and WindObserver anemometers. These allow for the display of wind speed and direction using high visibility LED technology. WindDisplay is available in two display formats (standard and marine) and 110 or 240 V ac operation with RS422 or NMEA inputs.

Research Anemometers
R3 Anemometers
The Solent R3 research range of anemometers has been designed with researchers in mind who need to determine fluxes using the eddy covariance technique. The range provides U, V, W and SOS (sonic temperature) outputs, which may be logged using the free Gill WindCom software. All units are served with common electronics and software and may be supplied with accessories that include cables, power supplies and sensor input units (analogue inputs).

Specifications | R3-50 | R3-100 / R3A-100 |
---|---|---|
Ultrasonic Output Rate | 50 Hz | 100 Hz |
Wind Speed Range | 0-45 m/s | 0-45 m/s |
Wind Direction Range | 0-359 no dead band | 0-359 no dead band |
Operating Temp Range | -40ºC to +60 ºC | -40 ºC to +60 ºC |
Moisture Protection | IP65 | IP65 |
External Construction | Aluminium & Carbon Fibre | Aluminium & Carbon Fibre |
Digital O/P Options | RS422 (RS232 optional) | RS422 & RS232 |
NMEA O/P | N/A | N/A |
Analogue Outputs | 7 (via optional PCIA) | 7 (via PCIA) |
Analogue Output Resolution | 14 bit | 14 bit |
Analogue Input | 6 (optional SIU) | 6 (optional SIU) |
Analogue I/P resolution | 14 bit | 14 bit |
Speed of Sound O/P | Available | Available |
Sonic Temp Output | Available | Available |
PRT Input | Via optional SIU | Via optional SIU |
Inclinometer | N/A | Option |
Head Symmetry | Symmetrical | Symmetrical / Asymmetric |
Calibration | Custom | Custom |
Transit Case | Optional | Supplied |
HS Anemometers
The Solent HS research range of anemometers has been designed with researchers in mind who need to determine fluxes using the eddy covariance technique.
The range provides U, V, W and SOS (sonic temperature) outputs, which may be logged using the free Gill WindCom software.
All units are served with common electronics and software and may be supplied with accessories that include cables, power supplies and sensor input units (analogue inputs).

Specifications | HS-50 | HS-100 |
---|---|---|
Ultrasonic Output Rate | 50 Hz | 100 Hz |
Wind Speed Range | 0-45 m/s | 0-45 m/s |
Wind Direction Range | 0-359 no dead band | 0-359 no dead band |
Operating Temp Range | -40ºC to +60 ºC | -40 ºC to +60 ºC |
Moisture Protection | IP65 | IP65 |
External Construction | Stainless Steel | Stainless Steel |
Digital O/P Options | RS422 & RS232 | RS422 & RS232 |
NMEA O/P | N/A | N/A |
Analogue Outputs | 7 (via optional PCIA) | 7 (via PCIA) |
Analogue Output Resolution | 14 bit | 14 bit |
Analogue Input | 6 | 6 |
Analogue I/P resolution | 14 bit | 14 bit |
Speed of Sound O/P | Available | Available |
Sonic Temp Output | Available | Available |
PRT Input | Available | Available |
Inclinometer | Fitted | Fitted |
Head Symmetry | Horizontal | Horizontal |
Calibration | Custom | Custom |
Transit Case | Supplied | Supplied |
WindDisplay